Ventilation of Buildings: A Paper Read Before the Society of Civil and Mechanical Engineers, at No. 7, Westminster Chambers, on the 10th of January, 1873. (With Additions).Kell Bros., 1873 - 30 páginas |
De dentro do livro
Resultados 1-5 de 5
Página 14
... shaft for conveying foul air into all the bed - chambers . I have seen in London a water - closet opening into the dining- room , but even this is hardly so objectionable as the usual position . The water - closet should , where ...
... shaft for conveying foul air into all the bed - chambers . I have seen in London a water - closet opening into the dining- room , but even this is hardly so objectionable as the usual position . The water - closet should , where ...
Página 14
... shaft , com- municating by means of pipes and valves with every room in the house . If thermo - ventilation alone is ... shafts for every street or block of houses . We provide for the carrying away of foul water , why not of foul air ...
... shaft , com- municating by means of pipes and valves with every room in the house . If thermo - ventilation alone is ... shafts for every street or block of houses . We provide for the carrying away of foul water , why not of foul air ...
Página 18
... shafts carried up the nearest building , tree , or other suitable object will answer the purpose , viz . , that of relieving the sewers of any pressure of gas . Their useful effect will be increased by the Archimedean screw cap as used ...
... shafts carried up the nearest building , tree , or other suitable object will answer the purpose , viz . , that of relieving the sewers of any pressure of gas . Their useful effect will be increased by the Archimedean screw cap as used ...
Página 19
... shafts . The following table , compiled by Mr. Haywood , " C.E . , showing the temperature of the City sewers , will not , I think , be out of place : - Time of Year . External Temperature in Shade . Temperature in Sewer . Highest ...
... shafts . The following table , compiled by Mr. Haywood , " C.E . , showing the temperature of the City sewers , will not , I think , be out of place : - Time of Year . External Temperature in Shade . Temperature in Sewer . Highest ...
Página 20
... shafts in which the passengers are partially stifled previous to the completion of the process in the tunnel . Having stated the conditions of the structure , let us consider what is required to be done . First we have a certain ...
... shafts in which the passengers are partially stifled previous to the completion of the process in the tunnel . Having stated the conditions of the structure , let us consider what is required to be done . First we have a certain ...
Outras edições - Ver todos
Termos e frases comuns
acid and water Admiralty air flue air per hour believe building burners called carbonic acid carpenter cast iron cause channel charcoal chimney cholera cisterns coal coal gas cold air combustion commonly consider cubic feet densities Desaguliers diameter difference difficulty draught efficient ventilation EGLESTON elements enter escape exit factories feet of air feet per hour form of cesspool foul air foul gas foul gases Fresh Air inlets furnace gas light grate heated heavier Intending tenants joists landlord light machine means mechanical ventilation nitrogen ornamental outer air oxide oxygen pass Peat perhaps persons Portland cement presence Pugging pumping putrid quantity of air readily respiration sanitary condition sanitary matters sanitary science sewage sewerage sewers shew shewn simple bodies Sir Jacob soil stations sulphuretted hydrogen Sulphurous Acid supply syphon thermo-ventilation tion town trap tubes tunnels valve ventilating pipe ventilating shafts wall waste water-closet