Ventilation of Buildings: A Paper Read Before the Society of Civil and Mechanical Engineers, at No. 7, Westminster Chambers, on the 10th of January, 1873. (With Additions).Kell Bros., 1873 - 30 páginas |
De dentro do livro
Resultados 1-5 de 6
Página 9
... escape unconsumed . In the case of the common fire , the products of combustion do not certainly escape into the room , but the air to supply the fire is required all the same , and I feel sure that not in one house in a hundred is this ...
... escape unconsumed . In the case of the common fire , the products of combustion do not certainly escape into the room , but the air to supply the fire is required all the same , and I feel sure that not in one house in a hundred is this ...
Página 11
... escape from drains and waterclosets . It is not too much to say that if architect and builder always did their duty , no foul air from any drain or closet ought ever to enter a house , and that the negligence of one and the ignorance ...
... escape from drains and waterclosets . It is not too much to say that if architect and builder always did their duty , no foul air from any drain or closet ought ever to enter a house , and that the negligence of one and the ignorance ...
Página 14
... escape into the chimney we increase the ventilating power very considerably . We have no longer to deal with the small difference before mentioned , but may calcu- late upon the whole height of the chimney , above the opening , through ...
... escape into the chimney we increase the ventilating power very considerably . We have no longer to deal with the small difference before mentioned , but may calcu- late upon the whole height of the chimney , above the opening , through ...
Página 14
... escapes through the upper one into the house . ( 3rd . ) All injurious escape may be prevented by ventilating the drain . A pipe should be connected with the syphon , on the summit of the bend between the water which closes the trap and ...
... escapes through the upper one into the house . ( 3rd . ) All injurious escape may be prevented by ventilating the drain . A pipe should be connected with the syphon , on the summit of the bend between the water which closes the trap and ...
Página 15
... escape of vitiated air C Floor Notes to Section A Indicates vitiated air space between Ceiling and Floor B Indicates vitiated air channel Fresh air inlet Fresh air channel с Pugging 11 D B┻收 A Joist Ceiling on B Note B.B Air Tubes to ...
... escape of vitiated air C Floor Notes to Section A Indicates vitiated air space between Ceiling and Floor B Indicates vitiated air channel Fresh air inlet Fresh air channel с Pugging 11 D B┻收 A Joist Ceiling on B Note B.B Air Tubes to ...
Outras edições - Ver todos
Termos e frases comuns
acid and water Admiralty air flue air per hour believe building burners called carbonic acid carpenter cast iron cause channel charcoal chimney cholera cisterns coal coal gas cold air combustion commonly consider cubic feet densities Desaguliers diameter difference difficulty draught efficient ventilation EGLESTON elements enter escape exit factories feet of air feet per hour form of cesspool foul air foul gas foul gases Fresh Air inlets furnace gas light grate heated heavier Intending tenants joists landlord light machine means mechanical ventilation nitrogen ornamental outer air oxide oxygen pass Peat perhaps persons Portland cement presence Pugging pumping putrid quantity of air readily respiration sanitary condition sanitary matters sanitary science sewage sewerage sewers shew shewn simple bodies Sir Jacob soil stations sulphuretted hydrogen Sulphurous Acid supply syphon thermo-ventilation tion town trap tubes tunnels valve ventilating pipe ventilating shafts wall waste water-closet