" Plates under 12} pounds per square foot when ordered to weight, shall not average a greater variation than the following : Up to 75 inches wide, 2^ per cent, above or 2^ per cent, below the theoretical weight. "
EXPERIMENTAL ENGINEERING - Página 135
de ROLLA C. CARPENTER - 1906
Visualização completa - Sobre este livro

The Materials of Construction: A Treatise for Engineers on the Strength of ...

John Butler Johnson - 1898 - 886 páginas
...following: Up to 75 inches wide, 2^ per cent above or 2J per cent below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent above...above or 3 per cent below the theoretical weight. ********** (i) For all plates ordered to gauge, there will be permitted an average excess or weight...
Visualização completa - Sobre este livro

Cambria Steel: A Handbook of Information Relating to Structural Steel ...

Cambria Steel Co - 1901 - 448 páginas
...following : Up to 75 inches wide, 2J per cent, above, or 2J per cent, below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above,...above, or 3 per cent, below the theoretical weight. f. For all plates ordered to gauge, there will be permitted an average excess of weight over that corresponding...
Visualização completa - Sobre este livro

Transactions of the American Society of Mechanical Engineers, Volume 23

American Society of Mechanical Engineers - 1902 - 982 páginas
...following : Up to 75 inches wide, 2$ per cent, above or 2-J per cent, below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above...above or 3 per cent, below the theoretical weight. * * * » * * * (g) For all plates ordered to gauge, there will be permitted an average excess of weight...
Visualização completa - Sobre este livro

Review of the Text of the American Standard Specifications for Steel ...

Albert Ladd Colby - 1902 - 114 páginas
...wide, 2 1/2 per cent. above or 2 1/2 per cent. below the theoretical weight. 75 inches wide up to too inches wide, 5 per cent. above or 3 per cent. below...above or 3 per cent below the theoretical weight. (i)- For all plates ordered to gauge, there will be permitted an average excess of weight over that...
Visualização completa - Sobre este livro

Review of the Text of the American Standard Specifications for Steel ...

Albert Ladd Colby - 1902 - 114 páginas
...wide up to 100 inches wide, 5 per cent. above or 3 per cent. below the theoretical weight. When 1oo inches wide and over, 10 per cent. above or 3 per cent. below the theoretical weight. (g). For all plates ordered to gauge, there will be permitted an average excess of weight over that...
Visualização completa - Sobre este livro

Manufacture & Properties of Iron & Steel

Harry Huse Campbell - 1903 - 914 páginas
...following: Up to 75 inches wide, 2% per cent, above or 2y2 per cent, below the theoretical weight, 75 inches wide up to 100 inches wide, 5 per cent, above...above or 3 per cent, below the theoretical weight, ********** (/) For all plates ordered to gauge, there will be permitted an average excess of weight...
Visualização completa - Sobre este livro

Materials of Engineering: Iron and steel. 9th rev. ed. 1903

Robert Henry Thurston - 1903 - 828 páginas
...following: Up to 75 inches wide, 2j per cent, above or i\ per cent, below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above...above or 3 per cent, below the theoretical weight. ******** (z) For all plates ordered to gauge, there will be permitted an average excess of weight over...
Visualização completa - Sobre este livro

Cambria Steel: A Handbook of Information Relating to Structural Steel ...

Cambria Steel Co - 1903 - 514 páginas
...following : Up to 75 inches wide, 2^ per cent, above or 2^ per cent, below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above...above or 3 per cent, below the theoretical weight. c. For all plates ordered to gauge, there will be permitted an average excess of weight over that corresponding...
Visualização completa - Sobre este livro

Standard Steel Construction: A Manual for Architects, Engineers and ...

Jones & Laughlin Steel Company - 1903 - 340 páginas
...wide, 2*4 per cent, above or 2% per cent. below the theoretical weight. 75 inches wide up to 231 106 inches wide, 5 per cent. above or 3 per cent, below...above or 3 per cent, below the theoretical weight. c. For all plates ordered to gauge there will be permitted an average excess of weight over that corresponding...
Visualização completa - Sobre este livro

The Manufacture and Properties of Iron and Steel

Harry Huse Campbell - 1903 - 906 páginas
...wide up to 100 inches wide, 5 per cent, above or 3 per cent, below the theoretical weight. When 1 00 inches wide and over, 10 per cent, above or 3 per cent, below Mie theoretical weight. ******.** (?) For all plates ordered to gauge, there will be permitted an average...